C150 flange mounted
15 kV Coupler
C150 flange mounted
Design: | flange mounted coupler (plug & receptacle) |
Contact assignment: | 3 phase, 1 ground, 1 pilot |
Rated voltage: | 15 kV 3 AC |
Rated withstand voltage: | 50 kV (1 min) dry |
Rated current: | 500 A |
Short circuit current: | 38 kA RMS |
Frequency: | 50 – 60 Hz |
Protection class: | IP 67H |
Ambient temperature: | -40 °C to +45 °C |
Shock resistance: | IK 10 |
Sealing: | EPDM and potting compound |
Cable cross section: | 35 – 240 mm² |
Material: | sea water resistant aluminum |
Surface treatment: | nature, epoxy powder coating |
Dimensions P / R (L x ø): | 229 x 311 mm / 210 x 311 mm |
Weight Plug / Receptacle: | 14,5 kg / 12,3 kg |
USP: | with separable fiber optic connection (optionally) |
C-Coupler-Series
- Fiber optic components have been developed to meet military specifications and requirements
- Three times the crush resistance and twice the tensile strength of non-metallic fiber optic cables
- Communication is not impacted even if rolled over by a tank
- Totally rodent proof
- Pollution resistance – designed for connection and disconnection on site
- High performance 2,5 mm termini and a split ceramic alignment sleeve assures superior performance and low optical insertion loss even under high shock and vibration
- Aluminum enclosure with durable anodization
- Stainless steel version on request
- APC terminals on request
- Single mode and multi mode operation possible
- Configurable design supports from 2 -18 fiber channels per connector
- Environmental sealing to IP68
Product: | Live current insulated cover |
Features: | Possibility of applying a voltage to the connector even when not plugged in |
Design: | Male design for C80D1-series Female design for C80D2-series |
Mating combability: | for 5, 8 and 15 kV coupler of C series |
Rated voltage | Male / Female | Pluggable with | Patton & Cooke | ||
250 A | M | PK8S-Mxy | PK8F-Mx | C80C1000x | 11E-073 |
F | RK8S-Fxy | RK8F-Fx | C80C2000x | 11E-073A | |
400 A | M | PL5S-Mxy | PL5F-Mx | 11D-110 | |
C80D1000x | C80D3008 | ||||
F | RL5S-Fxy | RL5F-Fx | 11D-110A | ||
C80D2000x | C80D3009 |
- The strain relief entrance fittings are included with the couplers C10, C80, C150, CEM150, C250 and P/R series. For the IMG series both, the original IMG and P&C entrance fittings can be used => depending on cable
- The entrance fitting gasket kits are normally not included with the C coupler series. For Europe, there are exceptions, so this point must be requested on a case by case basis. The same applies to the IMG series.
- The termination kits must be ordered separately with the C80, C150, CEM150 and P/R series. However no termination kits are required for the C250 coupler and the whole IMG series.